dri eaz drizair 1200 manual

The Dri-Eaz DrizAir 1200 Dehumidifier is a high-performance, rugged, and portable unit designed for efficient structural drying and water damage restoration in demanding environments.

Overview of the Device and Its Purpose

The Dri-Eaz DrizAir 1200 Dehumidifier is a high-capacity, portable unit designed to efficiently reduce humidity in enclosed spaces. It is ideal for water damage restoration, structural drying, and construction environments. The device removes moisture from the air, helping to dry materials like carpets, walls, and floors. Its rugged design and portability make it suitable for temporary or demanding applications, ensuring effective humidity control and preventing secondary damage caused by excess moisture. It is a reliable solution for professionals and restoration projects.

Key Features and Specifications

The DrizAir 1200 removes up to 18 gallons of water daily, featuring a hot gas bypass system for efficient drying and durable, portable construction for heavy-duty applications.

Technical Specifications and Performance Metrics

The DrizAir 1200 removes up to 18 gallons of water per day under optimal conditions and averages 8 gallons in controlled environments. It operates on 115v power, drawing 5.7 amps, and features a robust design weighing approximately 92 pounds. The unit is engineered for high-performance dehumidification, making it ideal for water damage restoration, structural drying, and construction sites. Its compact size and portability allow for easy placement in tight spaces, ensuring efficient moisture removal in demanding environments.

Design and portability

The DrizAir 1200 is designed for durability and ease of movement, featuring a rugged construction that withstands demanding environments. Weighing approximately 92 pounds, it is equipped with handles and wheels for easy transport. Its compact design allows for placement in tight spaces, making it ideal for water damage restoration and construction sites. The unit is built to operate efficiently in various settings, ensuring reliable performance while maintaining a small footprint for optimal portability.

Installation and Setup

Place the DrizAir 1200 against a wall, away from obstructions, ensuring unobstructed airflow. Connect the drainage hose for continuous operation or use the built-in tank. Follow manual guidelines for optimal setup and performance.

Proper Placement and Placement Guidelines

Place the DrizAir 1200 dehumidifier against a wall, ensuring it is away from obstructions to maintain proper airflow. Keep the unit in an open area to maximize efficiency. Avoid blocking the intake or exhaust vents, as this can reduce performance. For structural drying applications, position the dehumidifier in the most humid area to optimize moisture removal. Ensure the drainage hose is properly connected and routed to avoid kinks or obstructions. Maintain a clear path around the unit for safe and effective operation.

Drainage System Setup and Options

The DrizAir 1200 dehumidifier features a flexible drainage system to accommodate various setups. Connect the drain hose securely to the unit to ensure proper water discharge. Route the hose without kinks or obstructions to maintain consistent flow. For continuous operation, consider using a pump system, such as the Evolution LGR pump, to elevate water to a distant drain. Always follow the manufacturer’s guidelines for drainage setup to prevent issues and ensure optimal performance. Regularly inspect the hose for blockages or damage to maintain efficiency.

Operating Instructions

Press the power button to start the unit. Adjust settings via the control panel. Monitor humidity levels and airflow. Press DISPLAY to cycle through modes and data. Regularly inspect.

Understanding the Control Panel and Display

The control panel features intuitive buttons for mode selection, humidity adjustment, and display navigation. The DISPLAY button cycles through operational data, including DEHUMIDIFIER ON/OFF, TOTAL HOURS, and JOB HOURS. Press MODE to switch between operating settings. Use the UP and DOWN arrows to adjust the target humidity level. The display provides real-time feedback, ensuring optimal operation. Refer to the manual for detailed instructions on customizing settings and troubleshooting display functions.

Basic Operation Modes and Humidity Control

The DrizAir 1200 operates in standard and advanced modes. Standard mode maintains a preset humidity level, while advanced mode allows custom settings. Use the control panel to set the desired humidity between 30-90%. The unit automatically adjusts fan speed and operation to achieve and maintain the set level. For precise control, enable the dehumidistat. Regular monitoring ensures efficient performance and prevents over-drying. Adjustments are made via the UP and DOWN arrows, providing accurate humidity management for optimal drying conditions.

Maintenance and Filter Replacement

Regularly inspect and replace filters with Dri-Eaz 4-PRO filters (part no. 100250) for optimal performance. Clean the unit and check for obstructions to ensure efficient operation.

Filter Maintenance and Replacement Guidelines

Regularly inspect and replace the filter to ensure optimal performance. Use only Dri-Eaz 4-PRO filters (part no. 100250) for proper airflow and filtration efficiency. Other filters may compromise performance. Replace filters every 1-3 months, depending on usage and environmental conditions. Each filter is individually wrapped to maintain effectiveness. Failure to use genuine Dri-Eaz filters may reduce dehumidification efficiency and lead to operational issues. Always follow the manual’s guidelines for replacement and maintenance to extend the unit’s lifespan and performance quality.

Cleaning and General Upkeep

Regular cleaning is essential to maintain the efficiency and longevity of the DrizAir 1200. Use a soft cloth and mild detergent to wipe down the exterior and internal components. Ensure the filter is clean or replaced as needed. Check and clear any obstructions in the drain hose or vents to ensure proper airflow and drainage. Avoid using harsh chemicals, as they may damage the unit. Regularly drain the condensate tank or ensure the drainage system is functioning correctly. Keep the unit away from direct sunlight and moisture to prevent damage. Proper upkeep ensures optimal performance and reliability.

Troubleshooting Common Issues

Reset the unit by unplugging and replugging it. Check error codes (e.g., ER 4 or ER 8) and refer to the manual for solutions. Ensure proper drainage and airflow for optimal performance.

Understanding Error Codes and Solutions

The DrizAir 1200 displays error codes like ER 4, ER 8, and ER 9. ER 4 indicates temperature or sensor issues—check the sensor cable or contact Dri-Eaz support; ER 8 suggests touchpad problems; press keys multiple times to resolve. ER 9 signals drain hose obstructions; inspect and clear blockages. Always unplug and replug the unit first to reset electronics. Refer to the manual or contact Dri-Eaz Service at 888-867-3235 for further assistance. Proper troubleshooting ensures optimal performance and prevents operational disruptions.

Resetting the Unit and Diagnostic Steps

To reset the DrizAir 1200, unplug it, wait a few seconds, and plug it back in. This may resolve electronic issues. For diagnostics, check the drain hose for kinks or obstructions and ensure proper airflow. If error codes persist, press and release each touchpad key to test functionality. If issues remain unresolved, contact Dri-Eaz Service at 888-867-3235 for professional assistance. Regular diagnostics ensure optimal performance and extend the unit’s lifespan.

Warranty and Service Information

The DrizAir 1200 is backed by a comprehensive 5-year warranty on the refrigeration circuit and 1-year on parts and labor. Contact Dri-Eaz Service at 888-867-3235 for assistance.

Warranty Details and Coverage

The Dri-Eaz DrizAir 1200 Dehumidifier is covered by a 5-year warranty on the refrigeration circuit and a 1-year warranty on parts and labor. This warranty ensures protection against defects in materials and workmanship. Coverage begins from the date of purchase and applies to the original owner only. Exclusions include normal wear, misuse, or unauthorized modifications. For warranty claims, contact Dri-Eaz customer service at 888-867-3235. Proper registration and adherence to maintenance guidelines may be required for full coverage eligibility.

Contacting Dri-Eaz Service Department

For assistance, contact Dri-Eaz Service Department toll-free at 888-867-3235. This service provides support for troubleshooting, repairs, and warranty-related inquiries. Customers can also reach out for guidance on maintenance or technical issues. Additionally, a network of authorized service centers is available for hands-on repairs and parts replacement. Ensure to have model and serial number information ready for efficient service. Visit the official Dri-Eaz website for contact forms, service center locations, and additional support resources.

Safety Precautions and Guidelines

Ensure safe operation by placing the unit away from corrosive substances and ensuring proper ventilation. Always follow manufacturer guidelines and use genuine Dri-Eaz replacement parts.

Important Safety Instructions for Use

Always place the unit away from corrosive substances like chlorine. Ensure proper ventilation and avoid blocking airflow. Do not use damaged power cords or expose the unit to water. Keep the dehumidifier away from flammable materials and avoid overloading electrical circuits. Regularly inspect the drain hose for kinks or obstructions. Never touch electrical components with wet hands. Follow all safety guidelines in the manual to ensure safe and effective operation.

Environmental and Usage Restrictions

Avoid using the dehumidifier in environments with corrosive substances like chlorine. Do not operate in explosive or flammable atmospheres. Keep the unit away from direct water exposure and ensure it is placed on a level, stable surface. Avoid using damaged power cords and prevent overloading electrical circuits. Do not use in areas with extreme temperatures or humidity levels beyond the unit’s design specifications. Always adhere to the manufacturer’s guidelines to ensure safe and effective operation in suitable environments.

Leave a Reply